Duct fittings and terminal units.
Industrial exhaust duct design.
Return duct systems.
Before discharging out the stack exhaust contamination can be reduced by filters collectors and scrubbers to maintain acceptable ai r quality.
9 2 central return.
This is a general introduction to the design of industrial ventilation systems with an additional discussion of two of the more common industrial ventilation applications.
Exhaust stack and air intake design strategies stack design strategies the dilution a stack exhaust can pr ovide is limited by the disper sion capability of the atmosphere.
Duct systems include straight lengths or sections of duct transitions elbows and bends enlargements or contractions hoods discharge stacks and hangers or supports.
Ventilation systems for ventilation and air handling air change rates ducts and pressure drops charts and diagrams and more.
9 1 distributed return.
No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical including photocopying.
Volume velocity x area.
The goal of stack design.
9 3 pressure balancing.
Industrial duct systems are used for supply or exhaust are under positive or negative pressure of heavy or light duty construction convey clean and dirty airstreams constructed of metal plastic or fabric materials and assembled together with flanges clamps slip fit or welded.
10 4 diffusers grilles registers.
Upon a final understanding of the exhaust volume the contaminants being collected and the velocity requirements sizing the ductwork for an industrial ventilation system can be determined with the flow rate equation q va.
Ivi can assist in the design of a new system or the redesign of an existing system.
Air ducts sizing air flow and required duct area.
A side duct should join the main one at a tapered progressive widening and at an angle of 30º or less recommended or up to 45º or if there is insufficient space.
10 1 duct fittings and transitions.
The angle of the widening section must not be greater than 15º.
Our products are used to serve a variety of needs including industrial ventilation dust extraction and pneumatic conveying.
Air ducts friction loss diagram a major loss diagram for air ducts imperial units ranging 10 100 000 cfm.
10 3 fire and smoke dampers.
Installing engineering controls is the preferred method of.
The larger perimeter also means more air will come into contact wit the material and this adds friction to the system.
Wood shops and paint spray booths.
Ivi s engineering and design team has years of experience designing and sizing industrial ductwork.
Design of ducts with side junctions side duct junctions.
Duct system design guide first edition 2003 mcgill airflow corporation mcgill airflow corporation one mission park groveport ohio 43125 duct system design i notice.
8 7 rules of duct design acca manual d residential duct systems 9 0.
Air ducts velocity diagram air flow volume duct size.
Friction in a system means the fan needs to work harder and this results in higher operating costs.