304 8 construction and protection.
Imc roof equipment clearance.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Permanent fall arrest restraint connector devices are considered equivalent to guards for worker safety on a roof.
In imc section 306 5 the code requirement permits portable ladders for access to equipment located on a roof of buildings or on elevated structures when the vertical distance that must be climbed is not more than 16 feet above grade.
A building owner wishes to install a safety harness for workmen in lieu of the guard.
The roof elevation at the hatch is approximately 9 feet above the floor below.
Equipment and appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending not less than 3 inches 76 mm above the adjoining ground.
The scope of this requirement is limited to locations where equipment or appliances are installed within 10 feet of a roof edge or other elevated walking surface and the vertical drop to the level below exceeds 30 inches.
Section 304 11 requires guards to be installed on the roof if the equipment is located within 10 feet of a roof edge.
Where appliances equipment fans or other components that require service are installed on a roof having a slope of three units vertical in 12 units horizontal 25 percent slope or greater and having an edge more than 30 inches 762 mm above grade at such edge a level platform shall be provided on each side of the appliance or equipment to which access is required for service repair or maintenance.
Appliances located in private garages and carports shall be installed with a minimum clearance of 6 feet 1829 mm above the floor.
The roof hatch is more than 10 feet from the edge of the roof.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Is the intent of the code to require guards on the open side of roof hatches when either the hatch is within 10 feet of the roof edge or the hatch is more than 30 inches above the floor.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.